What causes flame rollout on a pool heater?

Category: home and garden home appliances
4.8/5 (1,252 Views . 16 Votes)
The most common cause for these to plug up is running too cold of water thru them. This causes a lot of condensation in the burner chamber that causes the combustion by-products to condense out and build up inside the unit.



Also to know is, what causes flame rollout on a water heater?

Flame rollout. Typically caused by insufficient combustion air or blocked exhaust venting. Absent access panel, absent burner cover, rust, debris, flame roll out, and melted drain valve escutcheon.

Additionally, what can causes a flame rollout switch to trip? Rollout switches trip because flames are burning back where they are not supposed to be. Possible causes include a stopped up vent, a stopped up heat exchanger, low gas pressure, or a cracked heat exchanger. In the case of the plugged vent or heat exchanger.

Also question is, what are some possible causes of burner flashback?

The gas in the burner mixer may be ignited, producing a flashback. Flame rollout is actually a variation of floating flames, with flames reaching for air outside the combustion chamber. The basic cause is a lack of combustion air. This lack of air may be due to overrating of burners, poor draft or blockage of flueways.

What is flame rollout?

Flame rollout is a term used to describe the condition or situation in which combustion takes place outside the burner area of an appliance, such as a gas boiler. Flame rollout is a common problem with gas-fueled appliances.

37 Related Question Answers Found

What color should Flame be on hot water heater?

The flame of any natural-gas appliance should be blue in color (with maybe a little yellow at the very tip of the flame). The orange flame of your water heater indicates that the gas is not combusting efficiently, and it's a sure sign that your heater needs adjustment or repair.

Is it dangerous if the pilot light goes out on water heater?

A device called a thermocouple is heated by the pilot light flame. As long as the thermocouple remains hot, gas is supplied to the pilot light. If the pilot light goes out, the gas is shut off and there is no danger of gas accumulating because the pilot light is out.

What does a roll out switch do?

The rollout switches are placed as a safety device around the burner area to sense the hot flame or hot exhaust thus shutting down the furnace so you do not get a fire or get carbon monoxide poisioning.

What causes furnace fires?

A house fire is often the most likely consequence of using a faulty or unmaintained furnace. When too much natural gas is leaked into the air, it quickly builds up. Since it is a very volatile substance, it can easily explode and cause a fire in the home.

What does a yellow flame on a gas furnace indicate?


A yellow or orange flame means that too much gas and/or not enough oxygen is being used when burning. Another symptom is a black, sooty residue, as the gas does not burn cleanly.

What Colour should my boiler flame be?

What Color Should My Furnace Flame Be? The burner flames from your natural gas furnace should look blue or almost completely blue. A healthy natural gas furnace flame is characterized by a roaring blue flame with a light blue triangle in its center. There may be a tiny tip of yellow.

What causes soot in a boiler?

Causes of Soot Buildup
Soot is the inevitable result of burning fossil fuels, and boilers that run on gas or oil produce soot simply by doing their job. Large amounts of soot can be caused by a dirty, clogged or malfunctioning burner, inadequate draft or a low air-to-fuel ratio.

Can you reset a limit switch?

Consult your instruction manual before resetting your furnace's limit switch. The function of your furnace limit switch is to tell the fan when to turn off and on depending on the temperature in the home. It's possible to reset the switch at home when necessary by following a few simple steps.

How do you bypass the flame sensor on a furnace?

Actually, you can bypass the flame sensor. the flame sensor is just a way of exposing the voltage on the flame sensor wire to the furnace burner flames. So you can connect the flame sensor wire to a screwdriver and put the screwdriver into the flames.

What is the most likely cause of flames that are lifting off the burner?


What is the most likely cause of flames that are lifting off the burner? Too much primary air.

What is Burnback flashback?

An Overview of Flashback Mechanisms
Flame flashback can be defined as an upstream propagation of flame back into the burner. This can be caused by an imbalance in the local flame and flow speeds, when the former exceeds the latter. This is the mechanism that is normally associated with the concept of flashback.

What are some possible causes of delayed ignition?

Several things can cause delayed ignition, including:
  • Pilot flame problems.
  • Not enough gas coming from gas burners.
  • Too much gas coming from gas burners.
  • Dirty, rusty or clogged burner ports.

What controls the amount of gas entering the burner?

Adjusting the gas valve on the Bunsen burner changes the volume of gas flow; the more gas entering the burner, the larger the flame. The collar at the base of the barrel contains air holes to control the amount of oxygen reacting with the gas.

What happens if there is improper venting of the furnace?

Carbon Monoxide Exposure
Combustion byproducts, such as carbon monoxide, can lead to many ill effects. This includes headaches, dizziness, nausea, fatigue, and even death. When your furnace has a blockage or backdraft and cannot properly vent, combustion gases cannot escape.

What is the one advantage of a standing pilot for a gas fired space heater?


What's the one advantage of a standing pilot for a gas-fired space heater? A. Being able to be used where heat may only be used for a limited time such as a vacation property.

What happens if the pilot fails to light during a trial ignition?

52-3) What happens if the pilot fails to light during a trial ignition? If the pilot does not light or if the pilot flame current is too low and not steady, the module will not energize the main valve and the burner will not light.

What is the purpose of the draft diverter on natural draft units?

52-5) What is the purpose of the draft diverter on natural draft units? The draft diverter regulates the draft through the heat exchanger and prevents downdrafts from blowing into the heat exchanger.