How do you reset a Hayward Aqua Trol?
Accordingly, how do I reset my Hayward Aqua Rite?
Reset AquaRite Salt Chlorination Inspect Cell Light If the Inspect Cell Light is the only LED light flashing, then you can reset it by simply holding down the diagnostic button for 3 seconds, then release. The Inspect Cell indicator will now reset and will later come back on after another 500 hours of use.
Subsequently, one may also ask, how do you calibrate a Hayward Aqua Trol?
How to Recalibrate a Hayward Aqua Rite Turbo Cell
- Turn Salt System Off and On. With the pump running, take the power switch down to the “Off” position, and then back up to “Auto”.
- Average Salt Reading. Wait until the numbers stop changing.
- Assess the Salt Cell Reading.
Turn Salt System Off and On With the pump running, take the power switch down to the “Off” position, and then back up to “Auto”. You should hear a click within 10 or 15 seconds. When you do, press the diagnostic button five times in a row. The system will go through a recalibration process.