How do I test my pool bonding?

Category: home and garden home entertaining
4.1/5 (203 Views . 12 Votes)
Using an alligator clip, attach one end of the roll of wire to an exposed bonding wire at the equipment pad. Unroll the amount of wire necessary to reach the furthest component to be tested. Connect the other alligator clip end of the wire to one of the ohmmeter test leads.



In this regard, do swimming pools need to be grounded?

The electrical equipment for swimming pools must be grounded and connected by wiring methods in accordance with the NFPA 70 National Electric Code® (NEC®). The following must be grounded: all electrical equipment associated with the circulation system; pool motors.

Also, do Intex pools need bonding? Intex pools are sold as portable pools and that's the reason bonding isn't required. There's also a requirement that you unplug all electrical equipment before anyone entering the pool.

Likewise, how does pool bonding work?

Bonding is the process by which the electrical and metallic components of the pool are joined together with a wire to form a non-resistive path between the components. The goal of bonding is to connect, contain and prevent the transmission of any harmful electrical voltage to pool equipment, people and pets.

Does a resin pool need to be bonded?

If the pool is considered a "Storable Pool", then it does not need to be bonded and it must have a double insulated pump. Most above ground pools that are 42" deep or shallower are considered storable.

35 Related Question Answers Found

Do you have to bond a above ground pool?

You need to create a field around your swimming pool by attaching the bonding wire to the metal deck, pool equipment, metal pool wall, and even the water. Local state and federal building codes require all permanent above ground pools to get correctly bonded.

What is a bonding lug?

Bonding lug or wire missing
Pumps will often have a bonding lug to which a copper bonding wire is connected. These bonding wires may come loose or get pulled out and need to be re-connected properly. Pool heaters, filters and other equipment items that are metal, likewise should be bonded.

What size breaker do I need for pool pump?

A typical above ground pool pump will require a 20-amp breaker and use #12 gauge wire to deliver the electricity.

How much does it cost to wire an above ground pool?

Electricians charge $500.00 – $1500.00 to wire up an above-ground pool. Included in the cost should be all supplies. You will need an 18-inch deep trench to run the service from the breaker-box to the pool area.

Can I use an extension cord for my pool pump?

It's highly recommended never to use an extension cord to power a pump of an above ground swimming pool. A pool pump requires a great deal of power and that you can't provide with a normal extension cord. You'd need one with a #12-gauge wire or a #10-gauge wire.

What is difference between bonding and grounding?

Bonding and grounding differences. In bonding, the emphasis is on creating low-impedance electrical connections between two or more conductive (metallic) bodies that are not normally current-carrying. These bonded objects are usually but not always grounded.

Do you have to bond a pool?

Most of us are aware that the pool must be bonded, but since 2008 the National Electrical Code (NEC) has mandated that pool water shall be electrically bonded, not just metals in the structure of the pool itself.

What does it mean when a pool is grounded?

Grounding a Swimming Pool
Grounding refers to protecting people in the pool from a potential fault in the electrical system (in the main electrical panel or pool sub-panel). A fault in the electrical system refers to a higher than normal flow of electrical current.

Why do we need equipotential bonding?

Equipotential bonding, commonly just called bonding, is used to reduce the risk of equipment damage and personal injury. It involves joining together all metalwork and conductive items that are connected to an earthing system (also called a grounding system) so that they all have the same potential energy (voltage).

Do you need a GFCI for a pool pump?

According to 680.22(B), all 15- or 20-ampere, 125-volt or 240-volt, single-phase outlets supplying pool pump motors are required to be provided with ground-fault circuit-interrupter protection for personnel. GFCI protection for pool pump motors is required whether supplied by receptacle or direct connection.

Are Indoor Pools grounded?

Indoor pool facilities are typically bonded and grounded so they are safe. While bonded and grounded buildings that are bonded and grounded make it easier for lightning to travel to the ground without resistance, they are not safe when it comes to water.

What is a pool bonding grid?

The purpose of the bonding grid in the first place is to ensure every metal component around the pool has the same resistance. That's why the technical name for a bonding grid is an "equipotential bond," meaning all the metallic components in a pool or spa should have equal resistance.

What is a bonding wire?

Definition of 'bonding wire'
A bonding wire is a wire connecting two pieces of equipment, often for hazard prevention. To bond two drums, a bonding wire must be used, which is a copper wire with alligator clips. A bonding wire is a wire connecting two pieces of equipment, often for hazard prevention.

What is continuity bonding?

A continuity bond is the metallic connection that yields constant electrical contact between two metal structures. It is the bond that connects components of metal with wires leading to electrical continuity.

What is earth bonding?

Earth bonding is the act of connecting all metallic objects in a room, or house, to 'electrical earth'; usually a gas andor water pipe. Gas and water pipes run through the earth (ground) so are connected to the same earth, eventually, as the electrical earth of an electrical circuit.

Why do we test continuity?

A continuity test is an important test in determining the damaged components or broken conductors in a circuit. It can also help in determining if the soldering is good, if the resistance is too high for flow of current or if the electrical wire is broken between two points.