From Wikipedia, the free encyclopedia. An air purge system is used to flush electrical control equipment with clean air before it is turned on. This ensures that the functionality of the equipment is not affected or damaged by the contaminants from the surrounding environment.



Regarding this, what does purge mean on AC unit?

"Purging" is the process of clearing an air conditioner's (AC's) unit's internal lines and hoses. This is frequently done before recharging freon but. many newer model AC units, such as Honeywell units, purge the system on startup.

Beside above, how do you purge air from a refrigeration system? Air in the system can be removed by collecting the system gas in the condenser, leaving the condenser cooling water on and venting out the air from the top of the condenser because air will not be condensed in the condenser but remains on top of the condenser above the liquid refrigerant.

Also question is, what does purge light mean on Honeywell?

PURGE Solid when in purge (lasts 2 minutes at power-up and after a call for heat or cool). Blinking when the DATS sensor has failed, or the wires are shorted or open. Will blink for 3 minutes at power-up if DATS is not present.

What happens if air gets in AC system?

When air enters a refrigeration system, it collects in the top of the condenser and is trapped. Air will cause a reduction in condenser surface area, which will cause a high condensing pressure. Air can enter the refrigeration system through a leak in the low side of the refrigeration system.

36 Related Question Answers Found

How do I purge my AC with nitrogen?

Break the system vacuum with nitrogen introduced at the side port of the core tool. Break the vacuum with nitrogen to that equivalent to atmospheric pressure (760,000 microns) then purge nitrogen through the system at 1-3 psig. from the high to the low side letting it vent out the open port of the core tool.

What are purging?

Purging, which can include self-induced vomiting, laxative or diuretic abuse, enemas, and compulsive exercise, can also follow a small or relatively normal-sized meal. This is referred to as purging disorder. Bulimia nervosa is characterized by both bingeing and purging.

What is purging in refrigeration?

Refrigeration Systems Air Purging. Regardless of whether a system is charged with ammonia or a Freon refrigerant, the thermal efficiency of such systems will greatly improve when undesirable noncondensable gas (air) is removed. The process of removing air, which is colorless and odorless, is called purging.

What is a Zms sensor?

The Zoning Mixed Air Sensor, Model S1-ZMS, is a duct mounted sensor used with the S1-MMZ, S1- MMH3 and S1-ZMS4 Zone Control Panels. When the supply air temperature rises above the heating set point or below the cooling set point, the zoning panel will lockout the heating or cooling equipment.

How does an ammonia Purger work?


When the concentration of water in the shell side of the heat exchanger gets to about 20 percent, the Auto-Purger Plus stops collecting air, isolates the mixture of ammonia and water, and energizes two electric heaters to heat the ammonia water solution even hotter, and to much more effectively concentrate the water.

What is purging in HVAC?

From Wikipedia, the free encyclopedia. An air purge system is used to flush electrical control equipment with clean air before it is turned on. This ensures that the functionality of the equipment is not affected or damaged by the contaminants from the surrounding environment.

What does dat stand for in HVAC?

Discharge Air Temperature

What is the process of purging?

Purging is the act of removing the contents of a pipe or container and replacing it with another gas or liquid. Purging is crucial in pipeline, piping, welding and industrial process. It removes contaminants from the piping and vessels, which reduces chances of corrosion.

What does red light on Honeywell thermostat mean?

Thermostat red light flashing or stays on: This means the outdoor unit has shut itself off because of a problem, and it sends a signal to the thermostat, letting you know that there is a problem. When this happens, the indoor unit tends to keep on running because the indoor unit doesn't know there is a problem.

What is a discharge air temperature sensor?


The Discharge Air Temperature sensor is used to measure the temperature of the air that is emitted from the air ducts. The control module calculates the temperature delta and automatically adjusts the HVAC system to minimize this temperature difference.

What happens if you don't vacuum your AC system?

If you don't vacuum out an AC system prior to refilling it with refrigerant you will not get maximum performance because there will be minor amounts of air (humidity/moisture) in there. SO by vacuuming an AC system we reduce the pressure so that any water in the system will boil away at ambient temperatures.

Do you charge AC on high or low side?

The LOW side fitting is usually located on the suction hose or line that goes from the accumulator to the compressor. The HIGH side fitting is located on the line that goes from the compressor to the condenser.

How do you troubleshoot a refrigeration system?

To test for an inoperative power element:
  1. Stop the compressor.
  2. Remove the remote bulb from the suction line.
  3. Place bulb in a container of ice water.
  4. Start the compressor.
  5. Remove the bulb from the ice water and warm in hand. At the same time, check the temperature of the suction line at the evaporator.

What is used to remove moisture and air from refrigeration sealed?

Moisture can be removed from a refrigeration system by applying a vacuum. POEs hold moisture more tightly than mineral oil.

How do you get air out of an air conditioner without a vacuum pump?


We have developed a method of removing the air from a system without the use of a vacuum pump. The method requires the installation of an access valve on the high and low side of the system. 1 - With the new compressor installed, turn on the compressor and depress the access valve on the high side of the system.

What can cause air contaminated refrigerant?

Contamination can also be caused by mixed refrigerants. In other words, the pressure/temperature method cannot identify whether the higher readings are being caused by air in the refrigerant, or if they are being caused due to refrigerant cross contamination.

What is nitrogen used for in HVAC?

The two main areas nitrogen gas is used within HVAC are for brazing and pressure testing copper coil. Nitrogen is used during the brazing process to purge oxygen from the brazed surface. This reduces oxidation and gives a better adhesion and joint strength.