What does purge override mean?

Category: home and garden indoor environmental quality
4.5/5 (3,018 Views . 38 Votes)
When the zone panel cover is off, the EMERGENCY HEAT/PURGE OVERRIDE button is visible. When the panel is in Purge (at startup or after a call for heat/cool), pressing this but- ton stops the Purge, which saves time during installation or troubleshooting.



Subsequently, one may also ask, what does purge mean on AC unit?

"Purging" is the process of clearing an air conditioner's (AC's) unit's internal lines and hoses. This is frequently done before recharging freon but. many newer model AC units, such as Honeywell units, purge the system on startup.

Similarly, what does purge mean on a zone board? pdf's you need on Honeywell's site. The control ignores fan call when it receives a heat or cool call. It will also satisfy a heat call before switching over to a cool call. The purge is to purge the air out of the ducts.

Regarding this, what is purge mode?

Air purge system. From Wikipedia, the free encyclopedia. An air purge system is used to flush electrical control equipment with clean air before it is turned on. This ensures that the functionality of the equipment is not affected or damaged by the contaminants from the surrounding environment.

What happens if air gets in AC system?

When air enters a refrigeration system, it collects in the top of the condenser and is trapped. Air will cause a reduction in condenser surface area, which will cause a high condensing pressure. Air can enter the refrigeration system through a leak in the low side of the refrigeration system.

20 Related Question Answers Found

How do I purge my AC with nitrogen?

Break the system vacuum with nitrogen introduced at the side port of the core tool. Break the vacuum with nitrogen to that equivalent to atmospheric pressure (760,000 microns) then purge nitrogen through the system at 1-3 psig. from the high to the low side letting it vent out the open port of the core tool.

What is purging in refrigeration?

Refrigeration Systems Air Purging. Regardless of whether a system is charged with ammonia or a Freon refrigerant, the thermal efficiency of such systems will greatly improve when undesirable noncondensable gas (air) is removed. The process of removing air, which is colorless and odorless, is called purging.

What is purge override Honeywell?

When the zone panel cover is off, the EMERGENCY HEAT/PURGE OVERRIDE button is visible. When the panel is in Purge (at startup or after a call for heat/cool), pressing this but- ton stops the Purge, which saves time during installation or troubleshooting.

How does an ammonia Purger work?

When the concentration of water in the shell side of the heat exchanger gets to about 20 percent, the Auto-Purger Plus stops collecting air, isolates the mixture of ammonia and water, and energizes two electric heaters to heat the ammonia water solution even hotter, and to much more effectively concentrate the water.

What does purge mean on a furnace?


Purging is like opening the window on your furnace to let air in. It is required by the NFPA86 and should be done before each furnace heating system start-up. The purge of airflow removes gaseous combustibles in a furnace and replaces it with air.

How do you clean a purge solenoid?

Applying vacuum directly to the purge valve with a hand-held vacuum pump can test vacuum-type purge valves. The valve should open and not leak vacuum if it is good. With solenoid-type purge valves, voltage can applied directly to the solenoid to see if the valve opens.

What is the maximum pressure a nitrogen purge can be used at?

(Purging with the gas you will be using is recommended.) Maximum pressure 1000 psig.

What is purge pressure?

Purge is the process used to remove any potentially hazardous gas from the interior of the enclosure prior to pressurization. Pressurization is the process of creating a higher internal pressure that is provided by a protective gas supply, preventing any hazardous gas or dust from entering the enclosure.

What is the air pressure required for air purge system?

Most purging applications require a minimum enclosure pressure of 0.10 inches (2.5 mm) of water. One psi is equal to 27.7 inches of water. In some circumstances, a minimum enclosure pressure of 0.50 inches (12.7 mm) of water is required to protect against ignitable dust.

What is purging of boiler?


Furnace purging refers to the clearing of the entire flue gas path for any combustibles that are leftover in the furnace. This clearing function is accomplished by ambient air. This is a mandatory safety requirement before ignition of fuel and is an interlock in boiler startup.

What is the use of purge air blower in ESP?

ESP Purge Blower. Purge blowers pressurize the insulator compartments, or penthouses, to maintain the cleanliness of the housed components. Uninterrupted purge blower operation is critical to precipitator systems that operate under positive pressure.

What is a DAT sensor?

The C7835A1009 Discharge Air Temperature Sensor (DATS) is a duct-mounted temperature probe that provides capacity control of heating and cooling equipment. It is used only with Honeywell networked zoning.

How much does a zone board cost?

Zone control panel:$115 to $200 depending on its capabilities.

HVAC Zoning System Cost.
Number of Zones New Construction Existing Home
Two Zones $1,500 to $1,850 $2,000 to $2,500
Three Zones $1,850 to $2,100 $2,200 to $2,850