Can P trap installed backwards?

Category: home and garden home appliances
4/5 (248 Views . 31 Votes)
Take for example this P-trap connection at a Garbage disposal. At first glance it looks almost normal, when actually it is installed backwards. Well eventually the trap will clog up with debris and water will just not drain properly.



Herein, which way does a P trap go?

In a shower P-trap, can the lower curvature be backward? When you cement it together, the straighter side of the trap- which is not as curved- should be what the 90 degree piece is glued onto. Then the curved end should be connected to the shower drain. However, gluing the P-trap shouldn't affect the drainage.

Secondly, what is the difference between a J bend and a P trap? The J-bend beneath the sink is also referred to as the P-trap, the U-bend and sometimes even just the drain trap. While there are some subtle differences between each of these fittings, they all essentially mean the exact same pipe in a drain pipe system.

Similarly, how far below drain should P trap be?

According to the International Residential Code, the maximum vertical distance between the sink drain and the entrance to the p-trap is 24 inches.

How do you connect a P trap to a tailpiece?

Slide the short side of the P-trap onto the tailpiece that drops down from the sink drain. Move the P-trap up or down to align the trap arm with the opening in the wall. Use a hacksaw to cut the tailpiece if you can't move the P-trap higher up the tailpiece and the trap arm is below the wall drain fitting.

39 Related Question Answers Found

What does the P stand for in P trap?

A P-trap gets its name because it combines two 90 degree joints with a horizontal overflow pipe and gives the entire unit the shape of the letter “P.” One of the 90 degree joints exits the drain of the sink and then is joined to another which contains a water seal system that allows for water to flow into the overflow

Why is an S trap illegal?

The purpose of a trap is to prevent sewer gases, and possibly vermin, from coming in to the home. Back to “Straps – The reason “Straps aren't allowed is because they have the potential to suck, or 'siphon', water out of the trap as the water flows down the drain.

Which is better S trap or P trap?

The only difference between a P-trap and an S-trap is the horizontal length of pipe on the outflow side which allows you to connect the vent. Because the drain is under the sink, you may not be able to engineer a system of pipes that will allow you to run the vent up through the wall to connect with the main vent.

Why does my P trap smell?

A dried p trap will result in a sewer odor emitting from a sink that maybe hasn't been used in a while. A p trap is designed to use water to block the sewer gases from leaking up the drain. If a sink's p trap dies out this can result in a drain that smells bad.

Can the P trap be above the exit pipe?


You attach the p-trap directly to the drainage and manuever the p-traps exits into you existing drain. It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally. They both work and have seen it many times.

Who invented the P trap?

Alexander Cumming

How far can vent be from P trap?

909.1 Distance of Trap From Vent
SIZE OF TRAP (inches) SLOPE (inch per foot) DISTANCE FROM TRAP (feet)
11/4 1/4 5
11/2 1/4 6
2 1/4 8
3 1/8 12

Does every P trap need a vent?

3 Answers. All traps need venting in all cases. Without a vent, the water seal in the trap gets sucked out and sewer gases can enter the room.

Are all P traps the same size?

When replacing a P-trap, you should use the same type of trap you remove. Traps are made from ABS (black), PVC (white) or brass (either chrome-plated or natural colored). Traps come in 1 1/4 inch (standard bathroom sink) or 1 1/2 inch (standard kitchen sink) inside diameter sizes.

Does P trap have to be directly below drain?

The "P" trap SHOULD be directly under the drain, but no more than a few inches off center of it, if conditions require it.

Do shower drains have P traps?

Shower and bathtub drain pipes must incorporate a P-trap; otherwise the health and safety of anyone in the building will be jeopardized by sewer gasses entering the building. A trap will keep water trapped in the pipe, keeping sewer gasses from coming up the drainpipes.

What size is a shower P trap?

The usual size for a shower drain trap is 2 inches, which is the diameter of the trap. This size is the minimum size that is allowed, which means that you cannot install a trap with a smaller diameter, or the trap is not within code.

Are P traps required?

(1) Traps required. Each plumbing fixture, except listed toilets, shall be separately trapped by approved water seal “Ptraps. The “Ptrap must be installed at the center fixture when three such fixtures are installed. (3) Prohibited traps.

What is a trap arm?


Basically, it's a simple cup of water that keeps sewer air from communicating with the air you breathe. The trap arm is the portion of a fixture drain between a trap weir and its protecting vent. The trap weir is the point at the bottom of the trap arm pipe where it connects to the trap.

What is Q TRAP?

The Q Trap system is a hybrid Triple Quadrupole/Linear Ion Trap mass spectrometer. Different from conventional quadrupole, the Q3 of the Q Trap MS can work as either a standard quadrupole mass filter or a linear ion trap (LIT) with higher sensitivity than traditional 3D ion trap.

What is a gully trap?

A gully trap is a basin in the ground which receives piped wastewater from inside your home before it is emptied into the wastewater network. The basin has a water seal to prevent foul odours of the sewer reaching the surface, and a vent pipe that allows fresh air in.